home security blog

From a physical point of view the ThunderBolt is fairly heavy 6. 4 ounces and large 4. 8 x 2. 6 x 0. 5 inches HWD. For some this is not an issue and gives the phone a solid premier feel, but if you like a phone that fits lightly in your pocket this one might not be for you.

security services company

01.14.2007 | 34 Comments

$50, which is covered in our section on combination smoke and CO detectors. Both of these smoke alarms use wireless technology to create their interconnected network. If you already have a wired network in place, the First Alert 7010B Est. $20 is a photoelectric smoke detector to consider. Also sold under the BRK brand, this smoke detector can be used on the same network with pretty much all current BRK and First Alert interconnectable smoke and CO detectors. You don't get the talking technology found in the pricier First Alert models, but there are latching indicators so you can see which smoke/CO detector in the network initiated the alert.

free home security installation

01.14.2007 | 16 Comments

The plurality of wire terminals 720 include a first terminal and a second terminal configured to receive a power supply line and a ground line for driving the plurality of electronic components contained within the device housing 106. Specifically, in an example, each of the power supply line and the ground line includes a respective fork terminal coupled to a corresponding wire terminal 720, and fixed thereto by tightening a screw fastener. Under some circumstances, the doorbell camera 106 is mounted on a wall or doorframe surface in place of a conventional doorbell, and the plurality of wire terminals 722 are coupled to receive the power supply line and the ground line that were applied to drive the conventional doorbell. Alternatively, in some implementations, the electrical connector 722 is coupled to one or more electrical wires for receiving a power supply or exchanging data with another electronic device. In an example, both the plurality of wire terminals 720 and the electrical connector 722 are available on the rear exterior surface of the device housing 702. The electrical connector 722 is only connected in a factory for testing, calibrating and/or setting up the doorbell camera 106, while the plurality of wire terminals 720 are applied to provide the power supply in the factory and/or after the doorbell camera 106 is shipped to a customer. In some implementations, the rear exterior surface of the device housing 702 includes a plurality of recesses 724. For example, the plurality of wire terminals 720 is disposed within a first recess 724A, and separated by a separation 730 that protects the lines connected to the first and second terminals of the plurality of wire terminals 720 from being shorted to each other. A height of the separation 730 may be smaller than a depth of the first recess, and the depth of the first recess 724A is configured to be greater than a height of a connection formed between the plurality of wire terminals 720 and the power supply or ground line. Specifically, in the above example, when the screw fastener is used to fix the fork terminal of the power supply or ground line onto one of the plurality of wire terminals 720, the depth of the first recess 724A is configured to be greater than a total height summing a thickness of the fork terminal and a height of a screw head of the screw fastener. As such, when the power supply and ground lines are connected i.